The determination of the dissolved in- 
organic phosphate ee was carried out 
using an Auto-Analyzer II of the Technicon Co,, 
applying the phosphormolybdenum blue method, 
according to an analysis procedure of P, Mangelsdorf 
(1972). Two reagent solutions were used for analysis, 
Reagent Solution I contained sulphuric acid, ammonium 
molybdate, and potassium antimony tartrate, Reagent 
Solution II contained ascorbic acid, acetone, and 
"Levor IV" (Technicon), 
Flow rate of Reagent Solution I: 0,27 ml/min,. 
Flow rate of Reagent Solution II: 0.27 ml/min,. 
Flow rate of the seawater to be investigated: 
0.80 ml/min, 
Time of passage of the seawater through the whole 
system (from the sample taker to the cuvette):; 
ca, 8 min, 
No. of samples per hour: 10. 
Calibration substance: potr- iumdihydrogenphosnhate 
(KH„PO,). 
The dissolved oxygen was determined 
by titration according to H, Winkler, in the modified 
version used by K. Kalle (1939). 
Kalle, K, 
(1939): Einige Verbesserungen zur Be- 
stimmung des gelösten Sauer- 
stoffes im Meerwasser, 
Ann, Hydrogr. u,.marit. Met,673 
Ss, 267, 
Methodische Verbesserungen der 
Phosphat-Bestimmung im Meer- 
wasser mit dem Auto-Analyzser 
insbesondere für den Bordbe- 
trieb. 
Helgoländer wiss.,Meeresunters, 233 
S., 376 = 382, 
Mangelsdorf, P, (1972) 
*
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.