IN
10:26 — 10:39 Station GN037 (Große Fischerbank):
Secchi depth and Clean-CTD profile with rosette sampler for nutrients, metals, and
salinity. Water samples for artificial nuclides.
N&S: Bft. 5, 250°, 1003 hPa, Ta = 16.2 °C, cloudy, Tw= 16.1 °C, S = 34.77 psu.
13:48 — 13:58 Station GN038 (Kleine Fischerbank):
Secchi depth and Clean-CTD profile with rosette sampler for nutrients, metals, and
salinity. Water samples for artificial nuclides.
W&S: No wind data, 1004 hPa, Ta = 16.0 °C, partly cloudy, Tw= 16.7 °C, S = 34.73
DSU.
16:00: Bft 5, 300°, strong swell.
17:05 — 17:21 Station GNO038A:
Secchi depth and Clean-CTD profile with rosette sampler for nutrients, metals, and
salinity. Water samples for artificial nuclides.
W&S: No wind data, 1004 hPa, Ta = 16.0 °C, partly cloudy, Tw= 16.7 °C, S = 34.76
DSU.
Problems occurred with data transmission between CTD and deck unit. Checked all
plug connectors. Test on deck OK, will make a final check on next station.
20:34 — 21:07 Station GNO039 (east of Jyske Rev):
CTD profile with rosette sampler for nutrients and salinity. Water samples for artificial
nuclides. MERCOS-sampler for metals.
W&S: Bft. 4, 280°, 1004 hPa, Ta = 15.3 °C, obscured sky, Ty= 17.2 °C, S = 34.34
DSU.
One cable of the Clean-CTD was defect, changed to CTD
23:34 — 23:47 Station GNO39S:
CTD profile with rosette sampler salinity.
W&S: No wind data, 1004 hPa, Ta = 14.9 °C, obscured sky, Tw = 16.5 °C, S = 31.69
DSU.
Thursday, September 5'", 2019
Jy 02:56 — 03:23 Station GN801:
CTD profile with rosette sampler for nutrients and salinity. Water samples for artificial
nuclides. MERCOS-sampler for metals.
W&S: Bft. 36, 280°, 1003 hPa, Ta = 13.8 °C, obscured sky, Tw= 17.0 °C, S = 34.36
DSU.
06:16 — 06:52 Station GN802:
Secchi depth and CTD profile with rosette sampler for nutrients and salinity. Water
samples for artificial nuclides. MERCOS-sampler for metals.
W&S: Bft. 4, 240°, 1002 hPa, Ta = 13.8 °C, partly cloudy, Tw= 16.5 °C, S = 30.54
PSU.
10:31 — 11:15 Station GN803:
Secchi depth and CTD profile with rosette sampler for salinity. Water samples for
artificial nuclides. MERCOS-sampler for metals.
W&S: Bft. 5, 310°, 1002 hPa, Ta = 13.1 °C, partly cloudy, Tw= 16.6 °C, S = 30.29
DSU.
%