76
Table 20: Fractionation behaviour of the Florisil® clean-up for chlordane compounds carried out on two
different batches. Relative recoveries [%] of the total amounts are given. Tetrachloro- (TCN), octachloro-
naphthalene (OCN), the chlordane compound MC8 and 4,5-dichlorochlordene were evaluated as internal
standards (ISTD).
Compounds Column 1 Column 2
Pre-fraction
PCA-Fraction
Pre-fraction
PCA-Fraction
ISTD
13 Ci 0 -frani-Chlordane
<1
87
<1
95
OCN
<1
107
<1
106
TCN
44
56
25
49
MC8
5
87
<1
109
4,5 -Dichlorochlordene
97
9
74
<1
Chlordanes
frans-Chlordane
5
86
<1
99
rz.v-Chlordane
<1
87
<1
91
Fleptachlor
105
5
55
0
rz.v-Nonachlor
<1
89
1
96
frans-Nonachlor
41
47
61
28
5.3.7.4 Blank controls
Blanks were always equal to the detection limits due to a very stringent cleaning proce
dure of glass ware (heating to 450 °C overnight, see experimental in the annex) and
many safety measures such as separate glass ware, pretreatment of adsorbents at 600 °C
etc. The blank problem is very serious for PCA analysis, but hardly addressed in the
literature, which makes many data therein doubtful.
5.3.7.5 Recoveries
Chloroparaffins
Recoveries of PCA in biota were checked for the whole extraction and clean-up method
with spiked muscle tissue from mackerel. As can be seen from Table 21, recoveries
were good for PCA and the internal standard.