accessibility__skip_menu__jump_to_main

Full text : Characteristic features of different oil types in oil spill identification (BSH-Berichte, Nr. 31)

22

Fig.  15:  GCs  of  HFO  samples  containing  different  amounts  of  aromatics  from  cracking
processes  (aromatics  are  hardly  discernible  in  the  upper  right  sample  -  and  not
discernible  in  the  lower  right  sample).

Since  FIFOs  contain  different  amounts  of  high-boiling  compounds,  which  cannot  pass  the  GC
(see  2.3.1  Analysis),  proper  categorization  of  higher  HFO  grades  by  means  of  GC  techniques
is  hardly  possible.  The  IFO380  in  Figure  16  (upper  left  chromatogram),  can  hardly  be
differentiated  from  the  IFO180  (upper  right  sample).  As  a  very  vague  rule,  it  can  be  stated
that  higher-boiling  grades  are  often  recognized  by  a  higher  and  broader  UCM  in  the  highboiling
  region.  The  two  IFO30  (lower  samples)  can  be  easily  distinguished  from  such  oils
because  of  their  limited  boiling  range.

Fig.  16:  Gas-chromatograms  of  IFO380  (upper  left),  IFO180  (upper  right)  and  two  IFO30
bunker  oils  (below).
            
Waiting...